Auto-calibration on DELTA WASP 3MT INDUSTRIAL 4.0
February 29, 2024
|By Diego Villa
auto-calibration is an important process to ensure accurate 3D printing on your Delta WASP 3MT Industrial 4.0 printer. Follow these steps carefully to perform auto-calibration:
TIP: It is recommended to start auto-calibration when both the print bed and the extruder are already heated to the desired print temperatures.
POSITIONING OF CONTACT NOZZLE:
- Make sure the printer is turned off.
- Carefully position the nozzle so that it is in contact with the print bed.
LOOSEN THE CALIBRATION SENSOR SCREW:
- Find the screw that tightens the calibration sensor and loosen it so that the sensor can rest freely on the build bed by gravity.
TIGHTEN THE CALIBRATION SENSOR SCREW:
- Once the sensor is properly placed on the build bed, tighten the calibration sensor screw to secure it in place.
TURNING ON THE PRINTER:
- Turn on the Delta WASP 3MT Industrial 4.0 printer.
WAITING FOR THE “AUTOCALIB ENABLED” SIGN:
- Now wait for “AUTOCALIB ENABLED” to appear on the printer’s display. This indicates that auto-calibration has been enabled.
STARTING SELF-CALIBRATION:
- As soon as you see “AUTOCALIB ENABLED”, you can start the auto-calibration process. To do this, select the “PRINT” option and then “AUTOCALIB” from the printer’s menu.
WAITING FOR THE AUTO-CALIBRATION PROCEDURE:
- The auto-calibration procedure will begin and last a few minutes. Make sure the extruder is heated during this step.
RAISE AND LOCK THE CALIBRATION SENSOR:
- Once the auto-calibration has been successfully completed, raise the calibration sensor and lock it in the desired position.